Sex

DIN EN 12464-1 PDF

Buy DIN EN LIGHT AND LIGHTING – LIGHTING OF WORK PLACES – PART 1: INDOOR WORK PLACES from SAI Global. This document EN has been prepared by Technical Committee CEN/TC “Light and the secretariat of which is held by DIN. DIN EN – Light and lighting – Lighting of work places – Part 1: Indoor work places; German version EN German title: Licht und.

Author: Tojashakar Brall
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Education
Published (Last): 16 May 2006
Pages: 212
PDF File Size: 17.85 Mb
ePub File Size: 5.45 Mb
ISBN: 597-2-55839-495-9
Downloads: 67041
Price: Free* [*Free Regsitration Required]
Uploader: Mular

The right degree and uniformity of the lighting intensity lx have a considerable impact on how quickly and securely a visual task can be comprehended and carried out.

Need more than one copy? Your Alert Profile lists the documents that will be monitored.

We have no amendments or corrections for this standard. This standard is dij applicable for the lighting of outdoor and underground mining work places.

If the document is revised or amended, you will be notified by email.

Photometric requirements according to EN

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. This document specifies lighting requirements for humans in indoor work places, which meet the needs for visual comfort and performance of people having normal ophthalmic visual capacity. As the voice of the U.

Photometric requirements according to EN Agriculture and viticulture Table 1. Proceed to Checkout Continue Shopping. Please first verify your email before subscribing to alerts.

This document specifies requirements for lighting solutions for most indoor work places and their fn areas in terms of quantity and quality of illumination.

The lighting intensity should be increased considerably if the 12464- tasks demand accuracy or enhanced productivity. The recommended minimum values of the maintained lighting intensity are:.

  ADDSTRINGATTACHMENT PHPMAILER PDF

Offices, educational facilities and hospitals require brighter lighting. Already Subscribed to this document. Proceed to Checkout Continue Shopping. Dn requirements with respect to the safety and health of workers at work can be contained in Directives 124641- on Article of the EC treaty, in national legislation of member states implementing these directives or in other national legislation of member states.

The EN standard now defines the arrangement of the grid to guarantee the comparability of different lighting calculations: In addition recommendations are given for good lighting practice.

Photometric requirements according to EN 12464-1

You may delete a document from your Alert Profile at any time. Illuminance according to EN Offices, educational facilities and hospitals require brighter lighting. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server.

If possible, quadratic partitioning – ratio of length to width of a grid field between 0. Arrangement of the calculation and measuring 1246-1 grid The EN standard now defines the arrangement of the grid to guarantee the comparability of different lighting calculations: The ASR regulation takes precedence with regard to planning in Germany.

DIN EN Beleuchtung von Arbeitsstätten in Innenräumen | Deutsche Lichtmiete®

Besides differing terms and concepts, there are also different requirements that must be met in the individual application areas. Please first log in with a verified email before subscribing to alerts. Standards Subsctiption may be the perfect solution. Back Products Indoor lighting Continuous line luminaires and batten luminaires Luminaires with higher degree of protection Recessed luminaires Surface-mounted luminaires Suspended luminaires Downlights and spotlights Wall-mounted luminaires Free-standing and desktop luminaires Industrial luminaires Ballproof luminaires Trunking rails and trunking profiles Replacement diffusers Awards Outdoor lighting Post-top luminaires Suspended luminaires Bollard luminaires Pillar luminaires Wall- and ceiling-mounted luminaires Ground-recessed luminaires Spotlight Floodlight Awards Light management LiveLink light management system Energy-saving systems Colour control systems Manual controls Applications Office Lighting for offices References Industry Lighting for industry Industry 4.

  HITACHI DZ-GX5020A MANUAL PDF

Please first log in with a verified email before subscribing to alerts.

The recommended minimum values of the maintained lighting intensity are: As the voice of the U. This document does not specify lighting requirements with respect to the safety and health of people at work and has not been prepared in the field of application em Article of the EC treaty, although the lighting requirements, as specified in this Document, usually fulfil safety needs.

DIN EN 12464-1: Beleuchtung von Arbeitsstätten in Innenräumen

Please first verify your email before subscribing to alerts. This document is not applicable for the lighting of outdoor work places and underground mining or emergency lighting. Essential requirements for good lighting Quality criteria of lighting General requirements Specific lighting requirements Lighting of traffic zones and general areas in buildings Lighting of industrial activities and crafts Lighting of don and VDU workstations Lighting of design and CAD offices Lighting of sports facilities Lighting of health care facilities Lighting of geriatric care facilities and nursing homes Lighting of public areas Lighting of salerooms 12464- of educational facilities Lighting of traffic areas Lighting of car parks Lighting of further indoor spaces Agriculture Viticulture Greenhouses Fire stations Mood-oriented rooms Residential wn Photometric requirements according to EN Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

We have no amendments or corrections for this standard.